Use of Vacuum to Increase the Effectiveness of X-Ray Tube Maintenance
DOI:
https://doi.org/10.59247/jfsc.v1i3.33Keywords:
X-ray tube, maintenance, vacuum, automaticAbstract
Each device requires redundancy, including the X-ray machine. In an X-ray machine, there is an important component as the location for the creation of X-rays, namely the X-ray tube. This tube needs routine maintenance to increase the tube's lifetime. In addition, maintenance that was originally done manually, with this device can be done automatically and more quickly. In addition, maintenance that was originally done manually can be done automatically and faster with this device. X-ray tube oil vacuum is used as an effective solution for the maintenance of an X-ray tube machine that lasts for days. This device comes with easy use, equipped with two buttons and a display. This device can increase the productivity of both the device and the technician itself. The application of the use of X-ray tube oil vacuum is intended for hospitals and health facilities that have active X-ray machines. This device has been able to be built. Based on the results, it has a 2.5% error for the measurement at minimum and maximum pressure and a 3% error at -15 KPa pressure. The volume of the X-ray tube fully filled is always the same for each measurement. It can be concluded that this device can be effective in time because it only takes minutes to fill the X-ray tube up to full. Still, many parts can be improved and developed, such as the size and the weight.
References
M. U. Hadi, R. Qureshi, A. Ahmed, and N. Iftikhar, “A lightweight CORONA-NET for COVID-19 detection in X-ray images,” Expert Systems with Applications, vol. 225, p. 120023, 2023, https://doi.org/10.1016/j.eswa.2023.120023.
A. Rayan and A. S. Alaerjan, “An improved crow search optimization with Bi-LSTM model for identification and classification of COVID-19 infection from chest X-Ray images,” Alexandria Engineering Journal, vol. 76, pp. 787-798, 2023, https://doi.org/10.1016/j.aej.2023.06.052.
J. Yan, Z. Liu, S. Zhang, Y. Geng, Y. Zhang and G. He, "X-ray radiation of a 126 kV vacuum interrupter," 2012 25th International Symposium on Discharges and Electrical Insulation in Vacuum (ISDEIV), pp. 461-464, 2012, https://doi.org/10.1109/DEIV.2012.6412555.
G. J. Bootsma, H. Nordström, M. Eriksson, and D. A. Jaffray, “Monte Carlo kilovoltage X-ray tube simulation: A statistical analysis and compact simulation method,” Physica Medica, vol. 72, pp. 80-87, 2020, https://doi.org/10.1016/j.ejmp.2020.03.015.
J. Winter et al., “Clinical microbeam radiation therapy with a compact source: specifications of the line-focus X-ray tube,” Physics and Imaging in Radiation Oncology, vol. 14, pp. 74-81, 2020, https://doi.org/10.1016/j.phro.2020.05.010.
A. Espinosa-Rodriguez et al., “Design of an X-ray irradiator based on a standard imaging X-ray tube with FLASH dose-rate capabilities for preclinical research,” Radiation Physics and Chemistry, vol. 206, p. 110760, 2023, https://doi.org/10.1016/j.radphyschem.2023.110760.
L. Torrisi, M. Cutroneo, A. Torrisi, L. Silipigni, “Graphene oxide modifications by X-rays irradiations in air and vacuum,” Vacuum, vol. 215, p. 112283, 2023, https://doi.org/10.1016/j.vacuum.2023.112283.
R. Prokeš, T. Trojek, and L. Musílek, “Determination of X-ray tubes radiation beam characteristics with semiconductor pixel detectors,” Radiation Physics and Chemistry, vol. 172, p. 108771, 2020, https://doi.org/10.1016/j.radphyschem.2020.108771.
D. Hei, L. Jin, W. Jia, L. Zhao, A. Sun, and G. Xiong, “Development and test of a multi-target transmission X-ray tube based on the electron deflection in an electric field,” Vacuum, vol. 193, p. 110490, 2021, https://doi.org/10.1016/j.vacuum.2021.110490.
H. R. Vega-Carrillo, J. Vazquez-Bañuelos, G. E. Campillo-Rivera, M. G. Garcia-Reyna, C. A. Marquez-Mata, and M. Vasquez-Arteaga, “Doses and spectra, of leaking-out and scattered photons from X-ray tubes used in dentistry,” Applied Radiation and Isotopes, vol. 189, p. 110451, 2022, https://doi.org/10.1016/j.apradiso.2022.110451.
D. S. Desmond et al., “Investigation into the geometry and distribution of oil inclusions in sea ice using non-destructive X-ray microtomography and its implications for remote sensing and mitigation potential,” Marine Pollution Bulletin, vol. 173, p. 112996, 2021, https://doi.org/10.1016/j.marpolbul.2021.112996.
Y. She et al., “Pore-scale study of in-situ surfactant flooding with strong oil emulsification in sandstone based on X-ray microtomography,” Journal of Industrial and Engineering Chemistry, vol. 98, pp. 247-261, 2021, https://doi.org/10.1016/j.jiec.2021.03.046.
C. Straube, J. Meyer, and A. Dittler, “Investigation of the local oil distribution on oleophilic mist filters applying X-ray micro-computed tomography,” Separation and Purification Technology, vol. 311, p. 123279, 2023, https://doi.org/10.1016/j.seppur.2023.123279.
E. Galiano, “Some radiological, structural, and physical properties of a clinical X-ray unit oil,” Applied Radiation and Isotopes, vol. 191, p. 110562, 2023, https://doi.org/10.1016/j.apradiso.2022.110562.
H. H. Busta, J. Montgomery, B. Schwandt and A. Feinerman, "X-ray generation from miniaturized vacuum tubes with diameters ranging from 1 to 5 mm," 2005 International Vacuum Nanoelectronics Conference, pp. 78-79, 2005, https://doi.org/10.1109/IVNC.2005.1619493.
T. Hu, T. H. Kwan, H. Zhang, Q. Wang, and G. Pei, “Thermal performance investigation of the newly shaped vacuum tubes of parabolic trough collector system,” Energy, vol. 278, p. 127802, 2023, https://doi.org/10.1016/j.energy.2023.127802.

Published
How to Cite
Issue
Section
License
Copyright (c) 2023 Alya Izzaty Bika, Meilia Safitri, Erika Loniza, Bagus Roni Yusuf, Djoko Sukwono

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.